Common array manager - 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su -

 
 The Sun Storage Common Array Manager (CAM) 6.10 Update release is available only for Solaris OS management hosts. Oracle’s Sun Storage Common Array Manager (CAM) 6.10 software that includes the fix for the following CVEs is supported only on Oracle Solaris 10 SPARC and x86 platforms. If you are running the CAM software on Windows or Linux ... . Black out bingo

The Program calculates the sets, rises and phases of the sun and moon... The HPE Smart Storage Administrator (HPE SSA) is a web-based application... Trusted Windows (PC) download Sun Storage Common Array Manager Online Help 6.9.0.16. Virus-free and 100% clean download.These release notes cover the software released on the Sun StorageTek Common Array Manager Software 6.0.0 CD. The Release Notes consist of the following sections: Features in This ReleaseSun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.Sun Storage Common Array Manager (CAM) - Version 6.0 and later Sun Storage 2530-M2 Array - Version Not Applicable and later Information in this document applies to any platform. Goal. Sun Storage 2500, 2500-M2, and 6000 arrays support Dynamic Volume Expansion (DVE). DVE is an operation that allows the user-visible …SANtricity Storage Manager - Version 10.50 and later Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. The purpose of this document is to provide a description of how to review the details … Oracle’s Sun Storage Common Array Manager includes the following documentation integrated within the software: Sun Storage Common Array Manager online help Available via the “Help” button within the Sun Storage Common Array Manager browser interface. Service Advisor Provides guided, FRU-replacement procedures with system feedback for all Sun Storage Common Array Manager (CAM) - Version 6.0 and later Sun Storage Flexline 280 Array - Version Not Applicable and later All Platforms Goal. This article documents Sun StorageTek Flexline 280 (FLX280) Array's components firmware baseline bundled in each corresponding CAM release and patched versions.Sun Storage Common Array Manager: How to Save an Array Configuration for Duplication or Restoration (Doc ID 1007142.1) Last updated on JANUARY 30, 2022. Applies to: Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] ...Firmware. Firmware delivered with Sun Storage Common Array Manager software can be installed using the Install Firmware Baseline feature. However, moving from one major firmware release to another (6.x to 7.x) requires a utility specific to the array family.Setting Up Notification for Fault Management. The fault management features of Sun Storage Common Array Manager enables you to monitor and diagnose your arrays and storage environment. Alarm notification can be provided by: Email notification Simple Network Management Protocol (SNMP) trapsJun 4, 2023 · This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of verifying component firmware ... Sun Storage Common Array Manager Array Baseline Firmware Reference, Version 6.8.1. 2 2510_exmoor N1532-735843-002 nge/N1532-735843-002.dlp The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring.(Doc ID 1012806.1) Last updated on MARCH 24, 2021. Applies to: . Sun Storage Common Array Manager (CAM) - Version 5.0 and later. All Platforms. Goal. … Oracle’s Sun Storage Common Array Manager includes the following documentation integrated within the software: Sun Storage Common Array Manager online help Available via the “Help” button within the Sun Storage Common Array Manager browser interface. Service Advisor Provides guided, FRU-replacement procedures with system feedback for all Most people looking for Common array manager downloaded: Sun Storage Common Array Manager Online Help. Download. One Interface, Run-Anywhere Flexibility Now there's an easy way to manage your storage environment. Similar choice › Download common view exe free › Gnu common lisp 2.4.9 free download;This article documents Sun StorageTek Flexline 380 (FLX380) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support … The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options are also provided. クイックスタートガイド. このマニュアルでは、オラクルの Sun Storage Common Array Manager ソフトウェアをインストールする基本的な手順について説明します。. 以前のバージョンからアップグレードする場合、または追加情報が必要な場合は、『Sun Storage Common ... Common Array Manager alarm code xx.66.1040: A controller cache backup battery has failed. Refer to <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, 6000 and J4000 Arrays. Changes. No changes have occurred on the array, other than the automated … 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - Common Array Manager alarm code xx.66.1091: Battery Tray.xx.Battery.x has transitioned to an unknown state; SANtricity Storage Manager fault of BATTERY_UNKNOWN_STAT; Reference: <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, … 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - Array Technologies (NASDAQ: ARRY) has surpassed Wall Street projections four times, including the last quarterly EPS of 21 cents per share, 91% higher … Sun Storage Common Array Manager: How to Save an Array Configuration for Duplication or Restoration (Doc ID 1007142.1) Last updated on JANUARY 30, 2022. Applies to: Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] Oracle’s Sun Storage Common Array Manager includes the following documentation integrated within the software: Sun Storage Common Array Manager online help Available via the “Help” button within the Sun Storage Common Array Manager browser interface. Service Advisor Provides guided, FRU-replacement procedures with system feedback for all Sun Storage Flexline 380 Array Sun Storage Common Array Manager (CAM) - Version: 5.0 and later [Release: 5.0 and later] Sun Storage 6180 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Storage 6780 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest. Setting Up Notification for Fault Management. The fault management features of Sun Storage Common Array Manager enables you to monitor and diagnose your arrays and storage environment. Alarm notification can be provided by: Email notification Simple Network Management Protocol (SNMP) trapsThe Sun StorageTek[TM] Common Array Manager (CAM) has the ability to collect support based configuration and logs for Sun StorEdge[TM], Sun StorageTek [TM], StorageTek[TM], Sun Storage[TM] Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information.Sun Storage Common Array Manager (CAM) - Version 6.9 to 6.10 [Release 6.0] Information in this document applies to any platform. Symptoms. When attempting to launch Service Advisor from Sun Storage Common Array Manager (CAM), the following message appears: "Service advisor package not installed for this type of device."Common Array Manager alarm code xx.66.1040: A controller cache backup battery has failed. Refer to <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, 6000 and J4000 Arrays. Changes. No changes have occurred on the array, other than the automated …Sun Storage Common Array Manager (CAM) - Version 5.0 to 5.1 [Release 5.0] Oracle Solaris on SPARC (64-bit) Oracle Solaris on SPARC (32-bit) Oracle Solaris on x86-64 (64-bit) Oracle Solaris on x86 (32-bit) Symptoms. Execution of the RunMe.bin installer, or RunMe.bin -c, on Solaris[TM] Operating System, fails with:Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. Instead customers typically do remote scripting using the remote CLI …Common controller and disk array management tasks. You can perform various tasks to manage SAS RAID disk arrays. Use the information in this section to manage your RAID disk arrays. Using the Disk Array Manager The disk array manager is the interface for performing various tasks with disk arrays. Preparing disks for use in SAS disk arrays …See your Sun StorageTek Common Array Manager Software Installation Guide (part number 820-4193) or Sun StorageTek Common Array Manager User Guide for the J4000 Array Family (part number 820-3765). 5. Log in as root (Solaris and Linux) or as a user with administrator privilege (Windows) on the management host. 6.To Assign an IP Address to Each Ethernet Port. . Access the Sun StorageTek Common Array Manager software: Open a web browser and enter the IP address of the management host: https://management-host:6789. management-host is the IP address of the machine where you installed the management software.Most people looking for Common array manager downloaded: Sun Storage Common Array Manager Online Help. Download. One Interface, Run-Anywhere Flexibility Now there's an easy way to manage your storage environment. Similar choice › Download common view exe free › Gnu common lisp 2.4.9 free download;Mar 9, 2022 · Goal. Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and stopping the JWC service is done when troubleshooting login problems, making JWC configuration changes, installing a JWC patch, or installing a legacy JWC application. vi Sun StorageTek Common Array Manager ユーザーズガイドオープンシステム用• 2010 年 2 月 FMS エージェントの構成 65 アレイの健全性の監視の有効化 67 アラームとイベントの監視 67 アラーム情報の表示 68 アラームの管理 70 アラームの承認 70 1 つまたは複数のアラーム ... Sun StorageTek Common Array Manager Software Release Notes, Release 6.1: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.1: HTML: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.1: PDF: Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version …You’ll find the most current information about Sun StorageTek Common Array Manager software in these 6.1.1 version Release Notes, including features, release ...Common controller and disk array management tasks. You can perform various tasks to manage SAS RAID disk arrays. Use the information in this section to manage your RAID disk arrays. Using the Disk Array Manager The disk array manager is the interface for performing various tasks with disk arrays. Preparing disks for use in SAS disk arrays …Sun Storage Common Array Manager Quick Start Guide, Version 6.8.x This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see the Sun Storage Common Array Manager Software Installation and Setup Guide.(Doc ID 1012806.1) Last updated on MARCH 24, 2021. Applies to: . Sun Storage Common Array Manager (CAM) - Version 5.0 and later. All Platforms. Goal. …Chapter 1 Sun Storage Common Array Manager Software Release Notes. Use this document for instructions about how to download the latest Oracle's Sun Storage Common Array Manager software and learn about new features, related documentation, system requirements, notable bug fixes, and known issues for the CAM 6.9.0 product release. The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.0: Enhancements to Auto Service Request (ASR) functionality. Support for Sun StorageTek FLX240, FLX280, and FLX380 Arrays. Hi! I have Sun StorageTek 2540 FC array and CAM works very slowly - I can wait for software response even more than 2 minutes... I run this software on Windows machine with Firefox Web Browser but spe | The UNIX and Linux Forums You’ll find the most current information about Sun StorageTek Common Array Manager software in these 6.1.1 version Release Notes, including features, release ... Sun StorageTek Common Array Manager Release Notes, part number 820-5749-12. Common Array Manager Software Features. The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM software includes …Mar 24, 2021 · Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. There are several components of the Sun StorageTek[TM] Common Array Manager (CAM) software : Solaris Web Console(SWC) Browser/Remote sscs interface(BUI/CLI) Fault Management Service(FMS) Storage Lifecycle Manager(SLM) In Band Proxy for RAID devices Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and … Sun Storage Common Array Manager: How to Save an Array Configuration for Duplication or Restoration (Doc ID 1007142.1) Last updated on JANUARY 30, 2022. Applies to: Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage Common Array Manager (CAM): How to Upgrade Firmware for Sun Storage 2500, 2500-M2, 6000 Arrays, J4000 JBODs, and F5100 Flash Arrays. (Doc …This document describes a possible problem in Sun Storage Common Array Manager (CAM) version 6.9.0.20 on Solaris that can prevent registration of arrays. CAM 6.9.0.20 involves the installation of CAM 6.9 and then the addition of either <Patch 147416-02> (Solaris SPARC) or <Patch 147419-02> (Solaris x86). Array registration in …The Sun StorageTek Common Array Manager CLI Guide describes the commands in the sscsCLI. Consult the hardware installation guide for your array for information about the initial physical installation of an array. Related Documentation In addition, the Sun StorageTek Common Array Manager includes the following online documentation:This article documents Sun StorageTek Flexline 380 (FLX380) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support … From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page. Sun Storage Common Array Manager: How to Save an Array Configuration for Duplication or Restoration (Doc ID 1007142.1) Last updated on JANUARY 30, 2022. Applies to: Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] ...This document shows how to upgrade firmware on Sun Storage 2500, 2500-M2, 6000 Arrays, J4000 JBODs, and F5100 Flash Arrays using Sun Storage Common Array Manager (CAM) within the same top level firmware (from 06.xx to 06.xx or from 07.xx to 07.xx). For information on upgrading firmware from 06.xx to 07.xx, please refer to the … 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - Common Array Manager alarm code xx.66.1091: Battery Tray.xx.Battery.x has transitioned to an unknown state; SANtricity Storage Manager fault of BATTERY_UNKNOWN_STAT; Reference: <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, …Firmware. Firmware delivered with Sun Storage Common Array Manager software can be installed using the Install Firmware Baseline feature. However, moving from one major firmware release to another (6.x to 7.x) requires a utility specific to the array family.SANtricity or Common Array Manager report a critical fault of Host IO Card has Failed (xx.66.1150). SANtricity or Common Array Manager report a critical fault of Host IO Card is Degraded (xx.66.1300). SANtricity or Common Array Manager reports a critical fault of One or More Volumes not on their Preferred Path (xx.66.1010). Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI).For the Sun Storage J4000 Array Family, refer to the Sun StorageTek Common ... Sun Storage Common Array Manager: How to Save an Array Configuration for Duplication or Restoration (Doc ID 1007142.1) Last updated on JANUARY 30, 2022. Applies to: Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] Jun 12, 2019 · This article documents Sun StorageTek Flexline 380 (FLX380) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of ... Jun 20, 2019 · Purpose. Sun Storage Common Array Manager (CAM) is used for managing and monitoring many Sun Storage arrays. CAM's notification capabilities include on-screen alarms and events via the BUI, and CAM can also send notifications via email or SNMP. This document covers setting up SNMP notifications from CAM. OUTPUT. Sun Storage Common Array Manager Software Release Notes Release 6.10 for Solaris OS Host l. Review important late-breaking information about Sun Storage Common Array Manager 6.10. Download. Sun Storage Common Array Manager Version: 6.10.0 Third Party License README l. This Third Party License README document applies to Sun Storage ... このドキュメントの目的は、StorageTek、Sun StorEdge、Sun StorageTekおよびSun Storage アレイのディスク障害の症状のトラブルシューティングを支援することです。. 現象. Common Array ManagerまたはSANtricityが、「 Failed Hot Spare or Unassigned Drive(ホットスペアの失敗または ... Sun Storage 2530-M2 Array - Version Not Applicable and later All Platforms Goal. This document describes the significance of a volume's "owning controller" and "preferred controller", and also explains how to change the "owning controller" setting of an individual volume via the Sun Storage Common Array Manager software.This article documents Sun StorageTek Flexline 380 (FLX380) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support …——————————————————————————-Sun Storage Common Array Manager 6.8.1 Please read the following license agreement carefully. Oracle has acquired Sun Microsystems, Inc. (“Sun”), you acknowledge that in all cases where the reference is Sun, Oracle will fulfill these obligations as successor in ...Sun Storage Common Array Manager Quick Start Guide, Version 6.8.x This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see the Sun Storage Common Array Manager Software Installation and Setup Guide.Array Technologies (NASDAQ: ARRY) has surpassed Wall Street projections four times, including the last quarterly EPS of 21 cents per share, 91% higher … Sun Storage Flexline 380 Array Sun Storage Common Array Manager (CAM) - Version: 5.0 and later [Release: 5.0 and later] Sun Storage 6180 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Storage 6780 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - Note - At the release of this document, there is currently no support for using the Common Array Manager to upgrade disk module and SAS-NEM firmware to a level that allows SAS-1 device coexistence with server modules with SAS-2 REMs.For more information on upgrading disk module and SAS-NEM firmware to a level that allows SAS-1/SAS-2 …Download popular programs, drivers and latest updates easily No specific info about version 6.9. Please visit the main page of Sun Storage Common Array Manager CLI on Software Informer.Sun Storage Common Array Manager supports these arrays: Sun Storage 6000 array series. StorageTek 2500 array series. StorageTek FlexLine array series. Sun Storage …Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. There are several components of the Sun StorageTek[TM] Common Array Manager (CAM) software : Solaris Web Console(SWC) Browser/Remote sscs interface(BUI/CLI) Fault Management Service(FMS)Sun Storage Common Array Manager (CAM) - Version 5.0 to 5.1 [Release 5.0] Oracle Solaris on SPARC (64-bit) Oracle Solaris on SPARC (32-bit) Oracle Solaris on x86-64 (64-bit) Oracle Solaris on x86 (32-bit) Symptoms. Execution of the RunMe.bin installer, or RunMe.bin -c, on Solaris[TM] Operating System, fails with:Sun StorageTek Common Array Manager Release Notes, part number 820-5749-12. Common Array Manager Software Features. The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM software includes …This chapter describes performing general administrative tasks applicable to all arrays. It contains the following subsections: “Using the Browser Interface” on page 2 “Administering Storage Arrays” on page 11 “Administering User Accounts” on page 17. 1. Using the Browser InterfaceSun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, 6000 and Flexline Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information. If you are using a …

The Sun Storage Common Array Manager (CAM) 6.10 Update release is available only for Solaris OS management hosts. Oracle’s Sun Storage Common Array Manager (CAM) 6.10 software that includes the fix for the following CVEs is supported only on Oracle Solaris 10 SPARC and x86 platforms. If you are running the CAM software on Windows or Linux ... . Varo log in

common array manager

——————————————————————————-Sun Storage Common Array Manager 6.8.1 Please read the following license agreement carefully. Oracle has acquired Sun Microsystems, Inc. (“Sun”), you acknowledge that in all cases where the reference is Sun, Oracle will fulfill these obligations as successor in ...Adding New Users and Assigning Roles. Creating Host Accounts. To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: root (or an administrative user for Windows) storage.%Program Files%\Sun\Common Array Manager\Component\sscs\bin. Volumes Supported on the Sun StorageTek 6130 Array up to 1022 . Bug 6540170 - Common Array Manager can be used to create up to 1022 volumes (volumes 0 through 1021) on the Sun StorageTek 6130 array. However, if the Access LUN is in use, up to 1023 volumes (volumes 0-1022) …Common Array Manager Software Features. The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays.Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, 6000 and Flexline Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information. If you are using a …This document describes a possible problem in Sun Storage Common Array Manager (CAM) version 6.9.0.20 on Solaris that can prevent registration of arrays. CAM 6.9.0.20 involves the installation of CAM 6.9 and then the addition of either <Patch 147416-02> (Solaris SPARC) or <Patch 147419-02> (Solaris x86). Array registration in …Mar 24, 2021 · Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. There are several components of the Sun StorageTek[TM] Common Array Manager (CAM) software : Solaris Web Console(SWC) Browser/Remote sscs interface(BUI/CLI) Fault Management Service(FMS) Storage Lifecycle Manager(SLM) In Band Proxy for RAID devices iv Sun StorageTek Common Array Manager CLI Guide • April 2009 Commands Used 21 Sample Data 21 Command Sequence 21 3. Monitoring and Administration Commands for All Arrays 27 add notification 27 Synopsis 27 Description 28 Options 28 Examples 29 add registeredarray 29 Synopsis 29 Description 29 Options 29 Examples 30%Program Files%\Sun\Common Array Manager\Component\sscs\bin. Volumes Supported on the Sun StorageTek 6130 Array up to 1022 . Bug 6540170 - Common Array Manager can be used to create up to 1022 volumes (volumes 0 through 1021) on the Sun StorageTek 6130 array. However, if the Access LUN is in use, up to 1023 volumes (volumes 0-1022) … The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page.Goal. This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. … Sun Storage Common Array Manager: How to Save an Array Configuration for Duplication or Restoration (Doc ID 1007142.1) Last updated on JANUARY 30, 2022. Applies to: Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a general ... .

Popular Topics